DeFelsko PRBFT-D Spare Probe PRBFT for PosiTector 6000 FT Coating Thickness Gauge

See More DeFelsko PosiTector 6000

DeFelsko PRBFT-D Spare Probe PRBFT for PosiTector 6000 FT Coating Thickness Gauge

See More DeFelsko PosiTector 6000
Price:
$500.00
    warrenty

    Product Description
    DeFelsko Spare Probes for PosiTector 6000 Coating Thickness Gauges For Use With 6000 Series
    Display Sold Separately

    Spare / Replacement probes for 6000 Series Coating Thickness Gauges. All probes are supplied with a NIST Traceablecalibration certificate.

    • Two (2) year probe warranty
    • Heavy-duty, gold-plated locking connector for industrial environments
    • Certificate of Calibration (Long Form) traceable to NIST or PTB included with every probe
    • Each probe retains its own unique calibration information (allowing full probe interchangeability)
    • Extended cables available for underwater or remote measuring. Specify length when ordering
    • Probes are PosiTector SmartLink compatible - wirelessly connect PosiTector 6000 probes to your smart device

    Probe Ordering Guide:

    F - for ferrous metals (steel and cast iron)
    N - for non-ferrous metals (aluminum, copper, titanium, etc.)
    FN - for all metal substrates - Automatically recognizes the substrate and takes a measurement


    lineIntegral Probes: PRBF, PRBN, PRBFN, PRBFT

     F, N, FNFT
    Range:0 - 60 mils | 0 - 1500 μ0 - 250 mils | 0 - 6 mm | 0 - 6000 μ
    *Accuracy:± (0.05 mils + 1%) 0 - 2 mils | ± (0.1 mils + 1%) > 2 mils | ± (1 μ + 1%) 0 - 50 μ | ± (2 μ + 1%) > 50 μ
    ± (0.5 mils + 1%) 0 - 100 mils | ± (0.5 mil + 3%) > 100 mils | ± (0.01 mm + 1%) 0 - 2.5 mm ± (0.01 mm + 3%) > 2.5 mm|

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    lineCabled Regular Probes: PRBFS, PRBNS, PRBFNS, PRBNAS, PRBFTS


    Probe ModelFS, NS, FNSNASFTS
    Range:0 - 60 mils | 0 - 1500 μ0 - 25 mils | 0 - 625 μ0 - 250 mils | 0 - 6 mm | 0 - 6000 μ
    *Accuracy:± (0.05 mils + 1%) 0 - 2 mils | ± (0.1 mils + 1%) > 2 mils | ± (1 μ + 1%) 0 - 50 μ | ± (2 μ + 1%) > 50 μ

    ± (0.02 mils + 1%) 0 - 4 mils | ± (0.1 mils + 3%) > 4 mils | ± (.5 um + 1%) 0 - 100 um | ± (2 um + 3%) > 100 um

    ± (0.5 mils + 1%) 0 - 100 mils | ± (0.5 mil + 3%) > 100 mils | ± (0.01 mm + 1%) 0 - 2.5 mm | ± (0.01 mm + 3%) > 2.5 mm

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    FXS Xtreme™

    Range:0 - 80 mils | 0 - 2000 μ
    *Accuracy:± (0.05 mils + 1%) 0 - 2 mils | ± (0.1 mils + 1%) > 2 mils | ± (1 μ + 1%) 0 - 50 μ | ± (2 μ + 1%) > 50 μ

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    lineCabled 90° Regular Probes: PRBFRS, PRBNRS, PRBFNRS

    Range:0 - 60 mils | 0 - 1500 μ
    *Accuracy:± (0.05 mils + 1%) 0 - 2 mils | ± (0.1 mils + 1%) > 2 mils | ± (1 μ + 1%) 0 - 50 μ | ± (2 μ + 1%) > 50 μ

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    Cabled Probe for Duplex Coatings: PRBFNDS

    Range0 - 60 mils | 0 - 1500 μ
    Minimum Zinc Thickness0.5 mil (13 μ)
    Paint Layer Accuracy Mils± (0.05 mils + 1%) 0 - 2 mils | ± (0.1 mils + 1%) > 2 mils
    Paint Layer Accuracy Microns± (1 μ + 1%) 0 - 50 μ | ± (2 μ + 1%) > 50 μ
    Zinc Layer Accuracy Mils± (0.1 mils + 1%) 0.5 - 2 mils | ± (0.2 mils + 1%) > 2 mils
    Zinc Layer Accuracy Microns± (2 um + 1%) 13 - 50 um | ± (4 um + 1%) > 50 um

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    Cabled 0° Microprobes: PRBF0S, PRBN0S

    Probe ModelF0S, N0S
    Range:0 - 45 mils | 0 - 1150 μ
    *Accuracy:± (0.02 mils + 1%) 0 - 4 mils | ± (0.1 mils + 3%) > 4 mils | ± (.5 μ + 1%) 0 - 100 μ | ± (2 μ + 3%) > 100 μ

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    Cabled 45° Microprobes: PRBF45S, PRBN45S

    Probe ModelF45SN45S
    Range:0 - 45 mils | 0 - 1150 μ 0 - 25 mils | 0 - 625 μ
    *Accuracy:± (0.02 mils + 1%) 0 - 4 mils | ± (0.1 mils + 3%) > 4 mils | ± (.5 μ + 1%) 0 - 100 μ | ± (2 μ + 3%) > 100 μ

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    Cabled 90° Microprobes:PRBF90S, PRBN90S

     F90SN90S
    Range:0 - 45 mils | 0 - 1150 μ 0 - 25 mils | 0 - 625 μ
    *Accuracy:± (0.02 mils + 1%) 0 - 4 mils | ± (0.1 mils + 3%) > 4 mils | ± (.5 μ + 1%) 0 - 100 μ | ± (2 μ + 3%) > 100 μ

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    Cabled 90° Extended Length Microprobe: PRBF90ES

    Range:0 - 45 mils | 0 - 1150 μ
    *Accuracy:± (0.02 mils + 1%) 0 - 4 mils | ± (0.1 mils + 3%) > 4 mils | ± (.5 μ + 1%) 0 - 100 μ | ± (2 μ + 3%) > 100 μ

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    High-Range Probes: PRBFT, PRBFTS, PRBFTRS, PRBFNTS

    Range:0 - 250 mils | 0 - 6 mm | 0 - 6000 μ
    *Accuracy:± (0.5 mils + 1%) 0 - 100 mils | ± (0.5 mil + 3%) > 100 mils | ± (0.01 mm + 1%) 0 - 2.5 mm | ± (0.01 mm + 3%) > 2.5 mm

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    Ideal for thick protective coatings such as epoxy, rubber, concrete liners, intumescent fireproofing and more: PRBFKS, PRBNKS

    Range:0 - 500 mils | 0 - 13 mm
    *Accuracy:± (1 mils + 3%) | ± (0.02 mm + 3%)

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    Measure non-conductive coatings on steel substrates: FHXS Xtreme™

    Range:0 - 400 mils | 0 - 10,000 μ
    *Accuracy:± (0.1 mils + 3%) | ± (2 μ + 3%)

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    Ideal for measuring thick epoxies, rubbers, fireproofing and other thick protective coatings applied to steel: PRBFJS

    Range:0 - 1.0 in. | 0 - 25 mm
    *Accuracy:± (0.01 in. + 3%) | ± (0.2 mm + 3%)

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    Measures intumescent paint and other thick protective coatings on steel: PRBFLS

    Range:0 - 1.5 inches | 0 - 38 mm
    *Accuracy:± (0.01 in. + 3%) | ± (0.2 mm + 3%)
    Minimum Surface Area:3.25 x 3.25 in. (83 x 83 mm)
    Minimum Substrate Thickness:0.1 in. (2.5 mm)

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line

    Measures very thick coatings on ALL metals: PRBFNGS

    Probe ModelFNGS
    Range:0 - 2.5 inches | 0 - 63.5 mm
    *Accuracy:± (0.01 in. + 3%) | ± (0.2 mm + 3%)
    Minimum Surface Area:10 x 10 in. (254 x 254 mm)
    Minimum Substrate Thickness: 0.2 in. (5 mm)
    Weight:0.8 lb. (0.4 kg)

    *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.


    line
    FAQ's - Frequently Asked Questions
    line

    Click to View DeFelsko PosiTector 6000 Frequently Asked Questions


    line
    Downloads
    line

    DeFelsko PosiTector 6000 Coating Thickness Gages - Full Instruction Manual
    DeFelsko PosiTector 6000 Coating Thickness Gages - Literature
    DeFelsko PosiTector 6000 Coating Thickness Gages - Quick Guide
    DeFelsko PosiTector 6000 Probe Details - Online
    DeFelsko PosiTector 6000 Coating Thickness Gages - Online Instructions Manual
    DeFelsko Accessories for Inspection Instruments - Online Catalog

    ADD TO CART THE ITEMS YOU WOULD LIKE TO PURCHASE
    Models Price