DeFelsko PosiTest AT Calibrator Adhesion Tester Accuracy Verification Kit

See More DeFelsko PosiTest AT Adhesion Testers

DeFelsko PosiTest AT Calibrator Adhesion Tester Accuracy Verification Kit

See More DeFelsko PosiTest AT Adhesion Testers
Price:
$2,495.00 - $2,820.00
    warrenty

    Product Description
    DeFelsko PosiTest AT Calibrator Adhesion Tester Accuracy Verification Kit
    High precision load cell for use with any PosiTector gage body
    Peak hold and real-time reading display


    Adhesion Tester Accuracy Verification Kit

    Ideal for verifying the accuracy and operation of adhesion testers and is an important component in fulfilling both ISO and in-house quality control requirements. The PosiTest AT Calibrator and included documents allow the user to certify the accuracy of PosiTest Adhesion Testers.

    • High precision load cell for use with any PosiTector gage body
    • Peak hold and real-time reading display
    • Hermetically sealed for protection against industrial environments
    • Compatible with all PosiTest Pull-Off Adhesion Testers (20 mm standoff required for 50 mm models, not included)
    • Fitted with a permanent steel 20 mm loading fixture (dolly). A conversion factor is used to verify other sizes


    line
    Kit Contents
    line

     
    Model DeFelsko ATC1
    PosiTest Calibrator
    DeFelsko PRBATC
    PosiTest Calibrator
    Probe only
    PosiTector gage body (Standard) ———
    High precision load cell (PosiTector gage body required)
    Calibration Procedure/Instructions
    Certificate of Accuracy Template
    Hard shell plastic case
    One year warranty
    Certificate of Calibration traceable to NIST
    Case Size 31 x 23 x 10 cm
    12.3 x 8.8 x 3.9 in
    31 x 23 x 10 cm
    12.3 x 8.8 x 3.9 in
    Shipping Weight 2.3 kg (5.1 lbs) 2.1 kg (4.7 lbs)
     


    line
    Features
    line

    Simple

    • Peak hold and real-time reading display
    • Compatible with all PosiTest AT Pull-Off Adhesion Testers (20 mm standoff required for 50 mm models, not included)
    • ‍Fitted with a permanent steel 20 mm loading fixture (dolly). A conversion factor is used to verify other sizes.
    • MPa and psi measurement scales

    Durable

    • Hermetically sealed for protection against industrial environments
    • ‍Ideal for field or laboratory use
    • ‍Portable — requires no external power source
    • ‍One year warranty

    Accurate

    • High precision load cell probe for use with any PosiTector gage body
    • Comes complete with Calibration Procedure, Instructions, and Certificate of Accuracy Template
    • Certificate of Calibration showing traceability to NIST included


    line
    Specifications
    line

    Range 110 - 3,500 psi 0.76 - 24 MPa
    Resolution 1 psi 0.1 MPa
    Accuracy ± 5.6 psi ± 0.039 MPa


    lineEasy Operationline

    1. Connect the adhesion tester's actuator to the PosiTest AT Calibrator's loading fixture.
    2. Apply pressure using the adhesion tester's normal operating procedure.
    3. Compare values from the adhesion tester and the PosiTest AT Calibrator.


    lineRelated Productsline

    DeFelsko PosiTest AT Pull-off Adhesion Testers

    • Measure adhesion of coatings to metal, wood, concrete and other rigid substrates


    line
    Downloads
    line


    F.A.Q.

    What is the purpose of the PosiTest AT Calibrator?

    The PosiTest AT Calibrator is used to verify the accuracy and operation of all PosiTest Adhesion Testers and is an important component in fulfilling both ISO and in-house quality control requirements. Contracts often specify that adhesion tests be performed with instruments that have measurement accuracy traceable to a National Metrology Institute such as NIST.

    Are there different options of PosiTest AT Calibrator to choose from?

    Yes. The high precision load cell measures in both MPa and psi scales and is available with or without a PosiTector gage body. A PosiTector gage body is required for use. The Calibrator is fitted with a permanent steel 20 mm loading fixture (dolly) and is compatible with all PosiTest Pull-Off Adhesion Testers—a 20 mm standoff is required for 50 mm models (not included). A conversion factor is used to verify other sizes.

    Can the PosiTest AT Calibrator be used with other manufacturers’ adhesion testers?

    No, not without user modifications to the loading fixture (dolly) and test points.

    What is the recommended Calibration Interval for the PosiTest AT Calibrator itself?

    We recommend customers begin their calibration intervals based on the recalibration date printed on the Certificate of Calibration for the load cell.