DeFelsko PosiTest FM Magnetic Pull-Off Coating Thickness Gage, Banana Gauge, Scale FM 0-80 mils

See More DeFelsko PosiTest Pull-off Gages

DeFelsko PosiTest FM Magnetic Pull-Off Coating Thickness Gage, Banana Gauge, Scale FM 0-80 mils

See More DeFelsko PosiTest Pull-off Gages
Price:
$350.00
    warrenty

    Product Description
    DeFelsko PosiTest FM Magnetic Pull-Off Coating Thickness Gages for Non-Magnetic Coatings on Steel
    Banana Gauge
    Application: Hot dip galvanizing, hard chrome metalizing, paint, enamel, plastic coatings on steel
    Scale FM: 0-80 mils
    Strong, wear resistant, ruby-tipped probe

    The DeFelsko PosiTest FM magnetic pull-off thickness gage, Banana Gauge, is ideal for the non-destructive measurement of non-magnetic coatings (hot dip galvanizing, hard chrome metalizing, paint, enamel, plastic coatings) on steel.


    line
    Kit Content
    line

    The DeFelsko PosiTest FM Coating Thickness Gage Kit includes everything needed for testing:

    • PosiTest FM Magnetic Pull-Off Coating Thickness Gage
    • Wrist strap and instructions in a high quality leather case with belt loops for your convenience
    • Certificate of Calibration showing traceability to PTB
    • Two (2) year warranty


    line
    Features
    line

    Simple

    • Positive visual and audible indicators to designate when thickness reading is established
    • “V” grooves in probe housing and Gage base allow correct positioning on cylindrical objects
    • Compact, lightweight, precisely balanced, independent of gravity – can be used in any position
    • GO/NO-GO button can be pre-set for rapid measurement
    • Probe contact and dial rotation all in a one-finger operation
    • Furnished with wrist strap and instructions in a high quality leather case with belt loops for your convenience

    Durable

    • Extra rugged housing, not affected by mechanical shock, water, acid or solvents
    • Unique overall design, fully supported, positive positioning, no pivoting tendencies during measurement
    • Can be used fully supported or with only the front probe area contacting the surface
    • Functions on a permanent rare-earth cobalt magnet
    • No batteries/electronics
    • 2 year warranty

    Accurate

    • Certificate of Calibration showing traceability to PTB included with every gage
    • Matching Calibration Standards and Procedures available for every model
    • Highly wear resistant Carbide Probe for longest life and continuous accuracy
    • Remove center of dial cover for easy calibration adjustment
    • Conforms to national and international standardsle


    line
    Downloads
    line

    DeFelsko PosiTest Pull-off Gages Magnetic Coating Thickness Gages for Non-Magnetic Coatings on Stee - Instruction Manual
    DeFelsko PosiTest Pull-off Gages Magnetic Coating Thickness Gages for Non-Magnetic Coatings on Steel - Literature
    Accessories for DeFelsko Inspection Instruments - Online Catalog

    F.A.Q.

    Is the DeFelsko PosiTest calibrated at the factory?

    The DeFelsko PosiTest arrives fully calibrated and ready to measure. A Long-Form Certificate of Calibration traceable to NIST or PTB is included, which documents actual readings taken by your instrument at our calibration laboratory on standards traceable to a national metrology institute. Beware of ‘Certificates’ or ‘Certificates of Conformance’ offered by competitors. These typically do not include actual instrument readings, and are often insufficient to meet common quality requirements. The DeFelsko PosiTest features a rare-earth permanent magnet that prevents any kind of drift over time. A DeFelsko PosiTest gage that sits unused on a shelf for several years will not drift or lose its calibration.

    Is the DeFelsko PosiTest intrinsically safe?

    “Intrinsically Safe” (I.S.) is commonly used to describe electronic products destined for a hazardous (explosive) operating environment. Owing to the mechanical (non-electronic) design of the DeFelsko PosiTest, it does not require certification as an “intrinsically safe” device.

    Is the DeFelsko PosiTest affected by the roughness of the steel substrate below the coating?

    All coating thickness gages are influenced to some degree by substrate roughness. It is generally accepted that coating thickness should be measured from the highest ‘peaks’ in the rough surface thus ensuring they are covered by the protective coating. However, coating thickness gages will instead measure the coating thickness from the effective magnetic surface, which is located somewhere between the highest peaks and deepest valleys of the profile.To compensate for the influence of substrate conditions (including roughness), measure the uncoated substrate/part at a number of spots to obtain a representative average value. This average value is called the “base metal reading” or “BMR”. Subtract the BMR from subsequent coating thickness measurements to obtain the thickness of the coating over the ‘peaks’ of the rough surface.

    Can the DeFelsko PosiTest measure nickel on steel?

    Yes, but it depends upon the particular type of nickel coating that has been applied to the steel.When nickel plating is deposited by a process of electrolysis (employing an electric current in the nickel bath), the resultant coating – commonly called “e-nickel” – is always conductive and magnetic to some degree and cannot be accurately measured by our gages when applied to ferrous or non-ferrous metals.Electroless nickel coatings are deposited by an autocatalytic process which does not involve the addition of an electric current. If the nickel bath in this process contains a minimum concentration of ~8% phosphorus, the resulting nickel plating is effectively non-magnetic and its thickness can be accurately measured on ferrous steel with a magnetic principle coating thickness gage such as the DeFelsko PosiTest.

    Does the DeFelsko PosiTest measure on hot surfaces?

    The operating temperature range of the DeFelsko PosiTest depends on the use case. The first case is where the measurement surface and the gage are both at the same temperature; in this case the operating range would be -10°C to 60°C (14°F to 140°F). The other case is where the DeFelsko PosiTest is at a “normal” room temperature but the measurement sample may be at a different temperature. In this case the DeFelsko PosiTest can measure on surfaces with temperatures ranging from -50°C to 100°C (-58°F to 212°F), so long as the instrument itself is kept within its operating range.

    Can the DeFelsko PosiTest be used underwater?

    Yes. The DeFelsko PosiTest features corrosion-resistant brass construction and can be immersed in fresh or saltwater. When used in saltwater, it is recommended to rinse with freshwater after use.

    Can the DeFelsko PosiTest be adjusted?

    While the DeFelsko PosiTest can be adjusted, this is not recommended for most applications. The permanent rare-earth magnet eliminates the need for adjustment, unlike other mechanical instruments. If a DeFelsko PosiTest is not functioning properly in accordance with NIST / PTB calibration standards we recommend the Gage be returned to us for a no-cost evaluation. Opening the DeFelsko PosiTest for purposes of cleaning, re-balancing and recalibration is not recommended.

    Does the DeFelsko PosiTest measure on non-ferrous metals, like aluminum?

    No. As a magnetic principle instrument, the DeFelsko PosiTest will measure the thickness of non-magnetic coatings applied to ferrous metals. Our popular DeFelsko PosiTest DFT Combo and powerful PosiTector 6000 N gage models are ideal for measuring the thickness of paint, anodize and other non-conductive coatings applied to non-ferrous metals.

    Is the DeFelsko PosiTest ‘automatic’?

    The DeFelsko PosiTest is a simple, manually-operated coating thickness gage. The GO/NO-GO button can be preset for taking rapid, accurate measurements.