Display easy to understand value and functions menus
Switch between digital real time graphs or analogue displays during measurement with just the flick of a finger
Two channels can be displayed simultaneously

The HORIBA LAQUA series marries advanced technology with stylish design and an easy-to-use touch screen interface. The Horiba LAQUA F-74 was developed as a durable meters offering long term reliability for laboratory professionals. Advanced functionalities and a wide array of electrodes provide high precision measurement with improved response time in a huge variety of applications.

line
Kit Contents
line

  • Horiba LAQUA F-74 Benchtop pH Ion ORP Conductivity Resistivity Salinity TDS Meter
  • Integrated Electrode Stand
  • Meter Cover
  • AC Power Adaptor
  • Instruction manual


line
Features
line

  • Display easy to understand value and functions menus
  • Switch between digital real time graphs or analogue displays during measurement with just the flick of a finger
  • Full on-screen support on the meter via an electronic user guide with colour pictures that can be called up at any time, featuring problem solver guide for calibration or measurement

Functions

  • Easy navigation for main unit and electrode inspections
  • Two channels can be displayed simultaneously
  • Periodic inspection mode JIS/Pharmacopeias/Digital Simulator
  • Full support for various country pharmaceutical pure water guidelines 
  • Customizable auto-hold function for calibration and measurement
  • Simultaneous connection to a GLP/GMP compatible and PC
  • Digital memory - maximum 2,000 sets of measurement data can be recorded
  • USB-PC communication and USB memory
  • Multi-language support (Japanese, English, Chinese, Korean)


line
Specifications
line

ModelLAQUA F-74 Dual Channel pH/ORP/Ion/EC/Res/TDS/Sal/Temp (⁰C)
pH Range-2.000 to 20.000 pH
Resolution0.01 / 0.001 pH
Accuracy± 0.001 pH
Calibration PointsUp to 5
Buffer OptionsUSA / NIST / NIST2 / China / Custom
ORP Range± 1999.9 mV
Resolution0.1 mV
Accuracy± 0.2 mV
IonRange0.000 μg/L to 9999 g/L (mol/L)
Resolution4 significant digits
Accuracy± 0.3% of full scale
Calibration PointsUp to 5
EC Range0.000 μS/cm to 19.99 mS/cm (k=0.1)0.00 μS/cm to 199.9 mS/cm (k=1)0.0 μS/cm to 1.999 S/cm (k=10)
Resolution0.05% of full scale
Accuracy± 0.6% of full scale (± 1.5% of full scale > 18.0 mS/cm)
Reference Temperature15 to 30 ºC (adjustable)
Temperature Coefficient0.00 to 10.00 % (adjustable)
Cell Constants0.1 / 1.0 / 10.0
Calibration Points4 (Auto / Manual)
Measurement UnitsAuto Ranging / ManualμS/cm, mS/cm, S/m
TDS Range0.01 mg/L to 1000 g/L
Resolution0.01 mg/L
Accuracy± 0.1% of full scale
TDS CurvesEN27888 / Linear (0.40 to 1.0) / 442 / NaCl

Resistivity Range
0.00 kΩ.cm to 199.9 MΩ•cm (k=0.1)0.000 kΩ.cm to 19.99 MΩ•cm (k=1)0.0 Ω.cm to 1.999 MΩ•cm (k=10)
Resolution0.05% of full scale
Accuracy± 0.6% of full scale (± 1.5% of full scale > 1.80 MΩ•cm)
Salinity Range0.00 to 80.00 ppt / 0.000 to 8.000 %
Resolution0.01 ppt / 0.001 %
Accuracy± 0.2% of full scale
Salinity CurvesNaCl / Seawater
Temperature Range­30.0 to 130.0 ⁰C
Resolution0.1 ⁰C
Accuracy± 0.4 ⁰C
Calibration OptionYes
Navigation FunctionYes
Memory2000
Auto Data-LoggingYes
Data SearchYes
Custom PrintingYes
Real Time ClockYes
Date / Time StampYes
Sample ID InputYes
Operator ID InputYes
Password SettingYes
Auto Stable / Auto HoldYes
Offset / Slope DisplayYes (independent acid and alkaline slopes depending on calibration)
Calibration Alarm LimitYes
Electrode StatusOn screen display
Diagnostic MessagesYes
DisplayTouchscreen color graphic LCD / dual channel display
LanguagesEnglish / Japanese / Chinese / Korean / Vietnamese
InputsDual BNC, dual phono, DC socket
OutputsUSB, RS232C, analog output
Power RequirementsAC adaptor 100 -­ 240V, 50/60 Hz
Electrode StandStand-alone
Weight700g
Dimensions170 (W) x 174 (D) x 73 (H) mm


line
Related Products
line

9615S-10D
Standard ToupH Electrode p/n 3200585100% / 3200366539

Standard ToupH Electrode 9615S-10D p/n 3200585100% / 3200366539

line

3552-10D
Platinum/Platinum black, glass-body, k=1.0 conductivity electrode with integrated temperature sensor

Standard ToupH Electrode 9615S-10D p/n 3200585100% / 3200366539

line

pH 4.01 Buffer Solution - Model No: 500-4

  • pH 4.01 ±0.02 Buffer Solution at 25°C 250ml

line

pH 7.00 Buffer Solution - Model No: 500-7

  • pH 7.00 ±0.02 at 25°C 500ml

line

pH 10.01 Buffer Solution - Model No: 500-10

  • pH 10.01 ±0.02 at 25°C 500ml

line

Conductivity Standard Solution Kit 103-S

  • 84 uS/cm Conductivity Solution at 25°C 250ml
  • 1413 uS/cm Conductivity Solution at 25°C 500ml
  • 12.88 mS/cm Conductivity Solution at 25°C 250ml
  • 111.8 mS/cm Conductivity Solution at 25°C 250ml


line
Downloads
line

Horiba LAQUA F-74 Benchtop Water Quality Conductivity pH/ION/COND Meter 3200575130 - Electrodes Accessories
Horiba LAQUA F-74 Benchtop Water Quality Conductivity pH/ION/COND Meter 3200575130 - Command-Reference
Horiba LAQUA F-74 Benchtop Water Quality Conductivity pH/ION/COND Meter 3200575130 - Instruction Manual
Horiba LAQUA F-74 Benchtop Water Quality Conductivity pH/ION/COND Meter 3200575130 - Quick Manual
Horiba LAQUA F-74 Benchtop Water Quality Conductivity pH/ION/COND Meter 3200575130 - Colour Touchscreen

ADD TO CART THE ITEMS YOU WOULD LIKE TO PURCHASE
Models Price
Discontinued