Delmhorst Delmhorst Moisture Meters

Delmhorst Instrument Co. is a leading manufacturer of high-quality moisture testing devices for a variety of applications and industries. Whether you need something simple and rugged or a top-of-the-line precision moisture testing device, odds are that we have the ideal moisture meter or thermo-hygrometer for your needs.


Below, you’ll find a list of the different industries Delmhorst serves and a brief explanation of each:

line

Agriculture


ABQ Industrial offers a variety of specialty moisture testing devices for agricultural purposes. From soil moisture meters that help improve irrigation efforts, to hay moisture meters for baled and loose hay, and grain moisture meters with more than 250 species corrections, we have the right tools for your needs.

line

Building Inspection


Realtors, property managers, and even private owners can benefit greatly from being able to accurately measure moisture in building materials such as concrete, wood, and drywall. Our specialized building inspection moisture meters help make testing moisture in structures fast, accurate, and easy.

Building inspections are a key part of the process in the sale of both residential and commercial property. Threats such as mold need to be quickly and reliably identified and remediated before a sale or lease agreement can be completed. How to test for mold and other major issues? With a variety of handheld moisture meters and humidity gauges for building inspection, of course!

Whether you prefer pin, pinless, or 2-in-1 devices, ABQ Industrial is sure to have the best moisture meter to meet your needs.

line

Flooring & Wood Products


Whether you’re a flooring installer or a lumber manufacturer, being able to accurately measure moisture in wood is crucial for maximizing product quality. Our wood moisture meters help you get fast and accurate moisture measurements in wood and flooring products.

In the flooring and wood industry, moisture remains a vital concern — whether the wood is in the mill, the kiln, or is being readied for installation. ABQ Industrial offers a variety of wood moisture meters professionals the world over

line

Restoration


Restoration experts may be asked to tackle challenges in a wide variety of situations — this means they need versatile tools that can go with them and provide accurate moisture measurements. ABQ Industrial offers a wide variety of restoration-focused moisture meters, thermo-hygrometers, and accessories that are invaluable for restoration experts.

Restoration experts have to make sure that they have fully identified the extent of moisture intrusion in a structure — and that they’ve completely remediated it before they declare the job finished. Moisture meters for restoration are a key tool in identifying moisture intrusion sources, determining the extent of the damage, verifying that dry-out is complete, and documenting the process for future reference if needed.

ABQ Industrial offers a variety of pin and pinless moisture meters for restoration experts

line

Leather


To achieve its ideal strength and finish, the moisture content of leather needs to be strictly regulated. Too much moisture too early could spoil leather before it finishes tanning; too little could make the leather brittle and dry. Our leather moisture meter option helps you maintain the perfect balance of moisture in leather.


Leather production involves complex multi-step processes where moisture must be closely monitored and controlled. Using the leather moisture meter will help minimize costly problems such as product and raw material waste, re-work, decreased productivity, and increased production costs

line

Paper


Whether you need to test paper pulp on a mesh conveyor or finished paper to ensure it’s appropriately dry, ABQ Industrial has the perfect answer to your paper manufacturing moisture testing needs! Our paper moisture meters are built to be used with a rolling-pin style electrode that makes testing moisture in a moving web of pulp easy.


Paper products are incredibly sensitive to moisture. Whether you’re plant supervisor, inspector, buyer, or salesperson, it’s crucial to monitor moisture levels of paper during production and upon delivery. Paper moisture meters are effective on kraft stock, corrugated stock, paper tubes and paper bales

line

Temperature / RH


Sometimes, knowing the relative humidity (RH) and temperature conditions at a jobsite are just as important as knowing the actual moisture content of the materials therein. Our thermo-hygrometers and temperature testing tools help you get accurate and reliable RH measurements.


The same superior quality found in our moisture meters is available in our thermo-hygrometers and thermometers. These versatile meters may be used in a variety of applications such as agriculture, flooring installation and inspection, and water damage restoration.


lineDelmhorst Moisture Meters FAQ's - Frequently Asked Questionsline


AGRICULTURE - HAY:

Why should i use a Moisture Tester?

Moisture content is one of the most important variables — and challenges — the high quality hay producer must face. Baling at proper Moisture levels is critical to the hay grower’s objective — to bale and store hay in a manner to reduce mold development and at the same time preserve leaves, color, and feed value. Using a Moisture Tester is the only way a farmer can be sure that his hay is being baled at the ideal Moisture levels.

How does a Moisture Meter operate?

Most probe-type meters operate on the principle of electrical resistance, utilizing the relationship between the Moisture content of the material and its conductivity. This relation is possible because Moisture is an effective conductor of electricity and hay acts as an effective insulator. The "reading" is made between the two metal contacts at the tip of the probe.

At what Moisture range can hay be baled?

Traditionally, the recommended Moisture content for baling hay without a preservative is between 18-20%.

If using a preservative, follow the instructions set forth by each particular preservative manufacturer. Smart use of a Moisture Tester in combination with preservatives and drying agents allows hay to be baled at higher than traditionally recommended Moisture levels.

In either case, do not attempt to bale hay before it is at an acceptable Moisture level, even when using a preservative.

What methods are commonly used for testing hay Moisture?

In The Windrow

  • Collect hay from the windrow and place it in a five or ten gallon container. Apply a multi-pin prod to the hay and press down on the handle. Take a reading. Mix the hay and repeat this procedure no less than three times.
    Then from the same area of the windrow, select up to five large, slower-drying stems and place one at a time across two adjacent points on the multi-pin prod and take readings. The average of these stem readings should be about two to five points higher than actual Moisture content.
  • Repeat these steps in different parts of the field and pay special attention to the areas where the hay is heaviest. Your decision to start baling should consider the amount of variation found among windrow readings as well as the average stem Moisture.

In The Bale

  • Since the interior of most bales is seldom uniform with regard to density and leaf/stem ratio, and it is impossible to obtain a truly "representative" sample, it is important to take a number of readings from various parts of a bale and average them. Pay close attention to the range of readings and the high readings. Drive the prod across the bale slices to obtain firmer, more uniform contact.

Random spoilage of baled hay can occur due to fluctuating field conditions, i.e. windrow size, soil Moisture, stand density, low spots, and shade. Therefore, it is imperative to check bales at several locations in the field.

In The Bale Chamber

  • The hay producer can install a micro-controller based Moisture Meter in the tractor cab and connect it to a sensor in the bale chamber to monitor Moisture while baling, without leaving the cab.
  • The microcomputer collects and processes eight readings that are accumulated every four seconds. The meter then displays the average and highest reading. This cycle is repeated every four seconds.

A microprocessor-based continuous monitor is an easy and reliable way to give the operator clear guidelines and a little less to worry about. Even though this method provides reliable information, we recommend that you take readings in several bales, especially at the beginning of baling, and as you see conditions change. The FX-2000 can be used for on-the-go Moisture monitoring or as a portable meter.

What affects the meter readings?

Besides Moisture content, factors which affect meter readings most are: Moisture distribution, crop variety, temperature of the hay, crop maturity, sample density, cutting, and the overall climatic conditions present. Cloud cover and high relative humidity result in more variable Moisture readings than a sunny, dry day with light breezes.

How can i know i'm receiving the most accurate results?

Because field conditions can change rapidly, accuracy guidelines must be considered in terms of "ranges", not specific points. Claims of accuracy should be taken with caution, because it is unlikely that such claims can be consistent. Expert evaluations of the same meter may yield different results, mainly dependent on the technician’s sampling procedure, conditioning and uniformity of the samples, difference in crop, and differences in oven test procedure. For optimum results, carefully read the owners manual provided with each meter.

Is there a way to make sure my meter is in calibration?

The primary or electrical calibration of the tester can easily be checked by the built-in calibration checkpoint feature or by using an optional Moisture content standard.

How do I keep a Delmhorst meter in good working condition?

Delmhorst Moisture Meters are well known for their ruggedness and ability to withstand years of rough handling. Like any testing instrument, a little care goes a long way toward trouble-free service:

  • Store the meter in clean, dry place
  • Change batteries and pins as needed
  • Keep the meter and electrode clean by using any biodegradable cleanser sparingly on external parts only.


BUILDING INSPECTION:

Why should i use a Moisture Meter?

Home Inspectors, Pest Control Operators and EIFS inspectors know that Moisture intrusion is the single most important factor affecting the integrity of building structures. Delmhorst Instrument Company offers Moisture Meter packages specifically manufactured to meet the needs of inspectors. Proper use of a Moisture Meter allows the inspector to easily identify the source of Moisture and to locate areas in the building that have been affected by moisture.

How does a Moisture Meter work?

There are two types of Moisture Meters typically used by the home inspector. Pin-type Meters, which utilize the principle of electrical resistance, use wood or other hygroscopic materials as an element in a circuit by driving two pins or electrodes into it.

Pinless Meters use radio frequency signals to penetrate the material being tested. There is no pin intrusion into the surface of the material you are checking.

Can i use a Moisture Meter to check for pest infestation?

Yes -- a few Meter readings in key locations of the structure will quickly indicate if the areas are safe or in danger of infestation. We recommend using pin-type Meters for pest control applications as the best way to identify the exact point of infestation behind walls and ceilings. The key to finding hidden Moisture is to use an electrode with insulated contact pins. These pins read only at their un-insulated pin tips, allowing the contractor to drive the pins into material at different depths, noting readings at each level of penetration.

A pinless Meter is a good way to identify infested areas, as long as you do not have to penetrate into a hidden material.

At what level of Moisture does infestation or decay occur?

Wood technologists and pest control experts agree that most fungi need at least 20% MC. Readings higher then 20% is susceptible to mold growth and decay. Readings in the 17%-20% are borderline and normally require further testing. On the other hand infestation can occur at much lower levels, especially in humid conditions. Old House Borer and Powderpost Beetles can attack wood that falls in the 12-13% range.

Which type of Moisture Meter works best for EIFS?

To quickly identify wet areas, a pinless Meter is easy to use. Pinless Meters offer the convenience of testing a large area quickly, and help you determine if further testing is required in certain spots.

Pinless Meters read Moisture closest to the source of the magnetic field, in this case, at the surface. Most pin-less Meters read at a depth from 1/2" to 1". Moisture that resides in the substrate or insulation may go undetected without using a deep penetrating electrode. It is also important to remember that any metal or other conductive material behind the EIFS may give false readings.

A pin type Meter, on the other hand, is the best way to identify the exact location of Moisture in the substrate and framing. A pin-type uses two pins that penetrate into the building at the users desired depth. When insulated contact pins are used, only the uncoated tips are exposed to the wood fiber, providing an accurate reading of Moisture content at various levels of penetration. Pin-type Meters are the only instruments that allow the inspector to identify exact location of Moisture at a given point.

Many EIFS inspectors use both types of Meters. They can quickly identify problem areas using a pin-less Meter, and also use a pin-type Meter to identify exact location of Moisture in the wood substrate.

Where does most Moisture intrusion occur in eifs clad houses?

Most Moisture intrusion occurs around windows, doors and any flashing. In many cases the Moisture intrusion is directly related to poor installation practices.

How can i find Moisture in the substrate or frame of the house.

The most effective way to check for Moisture in the substrate or frame is to us our 21-E electrode with 6" penetration pins. This method allows you to locate Moisture behind the EIFS without it having to be torn away.

How Do I Keep a Delmhorst Meter in Good Working Condition?

Delmhorst Moisture Meters are well known for their ruggedness and ability to withstand years of rough handling. Like any testing instrument, a little care goes a long way toward trouble-free service:

  • Store the Meter in clean, dry place
  • Change batteries and pins as needed
  • Keep the Meter and electrode clean by using any biodegradable cleanser sparingly on external parts only.

If you have any doubt about the working condition of your Meter, send it to Delmhorst. We can repair and re-calibrate your instrument to its original standards and return it to you quickly.


FLOORING & WOOD PRODUCTS:

Why should i use a Moisture Meter?

Structurally sound and beautiful in appearance, wood is the ideal raw material. Flooring professionals know that Moisture content is the single most important factor affecting the quality of a wood flooring installation.

To ensure quality from the manufacturer to the final installation, Delmhorst offers a full range of Moisture Meters that help minimize defects such as shrinkage, cracks, and splits. Years of experience, high-tech tools and controls, and premium grade wood cannot make a difference if Moisture content goes unchecked.

How does a Moisture Meter work?

There are two types of Moisture Meters typically used in the flooring industry. Pin-type Meters, which utilize the principle of electrical resistance, use wood or other hygroscopic materials as an element in a circuit by driving two pins or electrodes into it.

Pinless Meters use radio frequency signals to penetrate the material being tested. There is no pin intrusion into the surface of the material you are checking.

Which type of Moisture Meter works best for a flooring job?

To quickly identify wet areas in floors, pinless Meters are easy to use. They offer the convenience of testing a large area quickly, and help you determine if further testing is required in certain spots. A pinless Meter may also be used to determine if water-born finishes are dry and ready for a second application.

A pin type Meter, on the other hand, is the best way to identify the exact location of Moisture in sub-floors. The key to finding hidden Moisture is to use an electrode with insulated contact pins. These pins read only at their un-insulated pin tips, allowing the contractor to drive the pins into the floor and through to the sub-floor, noting readings at each level of penetration.

What are the ideal Moisture conditions for the sub-floor and wood flooring so problems can be avoided?

Flooring strips or planks - and the sub-floor - should be brought to equilibrium before installation. Best results are obtained when the wood sub-floor is within 4% MC of the flooring, maximum.

If the floor is on concrete, especially a slab on grade, the challenge is to be sure that the slab is dry and not likely to pick up Moisture later on. Please refer to the Operating Instructions section under PRODUCT SUPPORT for more info.

Why doesn't the Meter give Moisture content in percent on concrete?

Because the exact makeup of concrete is usually unknown, it is virtually impossible to provide a %MC calibration. Delmhorst Moisture Meters feature a 0-100 reference scale that provides “dry to wet” indications of the presence of Moisture. Factors that affect concrete Moisture readings include it's mix ratio and type, voids, and depth that the pin penetrates.

How does static electricity affect Meter readings?

In cold and/or dry climates, static charges may cause erratic Meter readings in the range below 8 percent. Measuring such high resistance under these conditions is difficult enough, but the winter months can make it more so. The analog Meter pointer "jumps" all over the scale or the digital display may flash erratic numbers. To minimize the effect of static:

  • Try not to let the electrode cable dangle.
  • Drive the electrode pins into the wood with the Meter turned off, and then turn the Meter on when you are ready to take the reading.
  • After driving the pins, place your hands next to them on each side of the electrode to help discharge the static from the board.
  • You can also try passing a damp cloth over the board's surface to pick up any static charges before driving the pins.

These suggestions are not guaranteed. However, depending on the conditions, any one of them can work, either alone or in combination with another.

Are there board width limitations in using Moisture Meters?

Board width is not a limiting factor when using a pin type Moisture Meter. As long as the pins make good contact, the Meter can be used on anything from small dowels to wide planks.

For accurate results with a pinless Meter, the material you're testing must be at least the width of the scanning area on the bottom of the Meter. Otherwise the Meter will not make firm contact with the board and may provide inconsistent, unreliable readings.

How Do Delmhorst Meters Handle Readings on Rough-Surfaced Lumber and Cupped Boards?

With a pin-type Meter, these conditions are not a problem. Just drive the pins as you would normally, insuring firm, positive contact and detect unknown gradients.

Pinless Meters, however, need firm contact to a flat surface so their readings on uneven surfaces may be unreliable.

How do i determine if the Moisture problem is in the finished floor or the sub floor?

In order to find this out, you must use a pin type Meter with insulated contact pins. First, take several readings in the layer just below the surface; then make a series of core readings, closer to the center of the board thickness. After you have noted these readings, hammer the pins through the flooring material until you make contact with the sub floor.

If your readings throughout this process are uniform, then there is not a Moisture problem. If readings increase as you go further into the floor, and again in the sub floor, this indicates that the sub floor is a source of Moisture.

How does temperature affect the accuracy of Meter readings?

After Moisture content and a Moisture gradient, if one exists, wood temperature is the most important factor affecting the accuracy of your readings. As wood temperature increases its electrical resistance decreases and indicated Moisture content rises. The lower the temperature, the lower the indicated Moisture content. Depending on the temperature and Moisture content, you may have to make a correction.

Does the glue used in plywood affect Meter accuracy?

In most cases, no. To verify this, use insulated pin to make individual tests by touching the outer ply, glue lines, and center plys. If the glue reads the same as wood, use the Meter on plywood as you would any solid material and take the readings at face value, without species correction.

How Do I Keep a Delmhorst Meter in Good Working Condition?

Delmhorst moisture meters are well known for their ruggedness and ability to withstand years of rough handling. Like any testing instrument, a little care goes a long way toward trouble-free service:

  • Store the meter in clean, dry place
  • Change batteries and pins as needed
  • Keep the meter and electrode clean by using any biodegradable cleanser sparingly on external parts only.

If you have any further questions on using a moisture meter for flooring applications


RESTORATION:

Why should I use a moisture meter for a water-damaged structure?

The only way to be sure you are properly drying a structure after water damage is to monitor the drying process with a moisture meter. Even if you have the most advanced drying equipment, you cannot be sure they are working effectively without the use of a moisture meter.

How does a moisture meter work?

There are two types of moisture meters typically used in the restoration industry. Pin-type meters, which utilize the principle of electrical resistance, use wood or other hygroscopic materials as an element in a circuit by driving two pins or electrodes into it.

Pinless meters use radio frequency signals to penetrate the material being tested. There is no pin intrusion into the surface of the material you are checking.

What type of meter works best for water-damaged structures?

To quickly identify wet areas in walls and floors, pinless meters are easy to use. They offer the convenience of testing a large area quickly, and help you determine if further testing is required in certain spots.

A pin type meter, on the other hand, is the best way to identify the exact location of water damage behind walls, in sub-floors, or in any other area where moisture may be hidden behind another surface. The key to finding hidden moisture is to use an electrode with insulated contact pins. These pins read only at their un-insulated pin tips, allowing the contractor to drive the pins into material at various depths, noting readings at each level of penetration.

When do I check the moisture of a structure?

As soon as you arrive at a job-site. It is crucial to check moisture levels in both water-damaged areas and areas that were not exposed to water. This enables you to establish a benchmark or target moisture level to reach at the end of the drying process. Use the meter continuously while drying, to confirm the progress of your work, and again before signing off. Remember, without a moisture meter, you have no way of knowing that you have dried the structure properly to "pre-loss" conditions.

What areas of a structure can be monitored using a moisture meter?

Check any area that has been exposed to water damage, namely wood floors, sub-floor, joists, studs or paneling. Also check for moisture in concrete sub-floors, drywall, insulation and behind trim and moldings.

Because Delmhorst moisture meters have different scales to measure %MC in wood, gypsum, and other non-wood building materials, it's easy to check all these areas with one moisture meter.

How can I check moisture levels behind baseboards and trim molding without removing them?

Use our 19-E/ST electrode. The flat blades of this electrode can be slid easily between the wall and trim, making it easy to check these hard to reach places, while leaving everything in tact.


WOODWORKING, INDUSTRIAL & MILL:

Why should i use a moisture meter?

Structurally sound and beautiful in appearance, wood is the ideal raw material. Delmhorst customers in the woodworking/lumber industry know that moisture content is the single most important factor affecting the quality of their products.

To ensure quality, from the mill and dry kiln to the finishing floor, Delmhorst moisture meters help minimize defects such as shrinkage, cracks, and splits. Years of experience, high-tech tools and controls, and premium grade lumber cannot make a difference if moisture content goes unchecked.

Are there different types of moisture meters?

There are two types of moisture meters commonly used in lumber and woodworking applications.

A pin-type uses two pins that penetrate into wood at the users desired depth. Pin-type meters are the only instruments that indicate the moisture conditions inside a board or a piece of wood. Using insulated pins, only the uncoated tips are exposed to the wood fiber, providing more accurate readings of moisture content at various levels of penetration. Using a pin type meter with insulated pins is still the most effective method to determine moisture gradient, which is the difference between shell and core moisture content.

Pinless moisture meters read moisture closest to the source of the magnetic field, in this case, at the surface. For quickly scanning finished product, a pin-less meter is a convenient way to identify a problem area. However, a pinless meter cannot differentiate between shell and core moisture content and will not detect a moisture gradient. Also, readings provided by a pinless meters are affected by surface moisture.

Please refer to the diagram below for a basic look at the difference between readings obtained from a pin-type meter compared to a surface meter.

This diagram illustrates that pin-type meters and surface meters provide different information about the moisture content in a board. Each technology may be appropriate for different applications. Before choosing a meter, it is important to understand these differences in readings and choose the type of meter best suited for your particular application.

How does a moisture meter work?

Using the principle of electrical resistance, pin-type meters use the board as an element in a circuit by driving two pins or electrodes into it. This method works because moisture conducts electricity well and dry wood is an effective insulator.

Most pinless meters use the capacitance method, which uses the relationship between the moisture content and the dielectric properties of the wood.

Both the resistance and the dielectric properties of wood change in direct proportion to its moisture content, within a specific range.

In what range of moisture content do pin-type meters operate?

Resistance-type meters express moisture content as a percentage of the oven-dry weight of the wood. These meters work best from the range of fiber saturation point (25 to 30 percent) down to around 6 percent. Below 6 percent, it's tough to make accurate, repeatable readings because of the high electrical resistance in really dry wood. This is particulary true at low relative humidity levels, generally below 30 percent.

Electrical accuracy of all Delmhorst meters is better than 0.5 percent between 6 and 12 percent moisture content; better than 1 percent between 12 and 20 percent moisture content; and better than 2 percent between 20 and 30 percent, or at fiber saturation point. You can check accuracy either through the internal check or with a Moisture Content Standard.

At what moisture content level do i minimize defects?

Acceptable moisture content depends on the final use of the wood. Wood for fine furniture should be dried to 6 to 8 percent in most areas of the country, with very little variation among pieces and between the shell and core.

Appropriate moisture content is also climate-driven. To determine the attainable moisture content - or equilibrium moisture content (EMC) - in your part of the country, hang small, thin samples of a wood species in your shop or plant and taking daily readings. When the samples' moisture content remains constant, they have reached the equilibrium level. This level will change from season to season, but you'll know the range within which to work. (Figure III)

How do i determine the distribution of moisture in a board?

Here's where Delmhorst recommends the use of a pin-type moisture meter.

First, to determine how the moisture is moving through a board, make a series of shell readings in the layer just below the surface; then make a series of core readings, closer to the center of the board thickness. The Delmhorst 26-ES electrode with insulated pins is the easiest and surest way to detect a moisture gradient.

Since the 26-E pinpoints are not insulated, two or three quick readings at different levels of penetration will indicate if the board is well seasoned, or properly dried. A normal gradient usually develops from the wetter core to the drier surface, with an average reading at between 1/4 to 1/5 of the board thickness. Even non-insulated pins, which measure the wettest fibers, will provide a good indication of how the wood is drying.

If you are using non-insulated pins, push the pins just about 1/16" into the surface, read the meter, and then push the pins to their full depth. For kiln-dried stock, the final reading should be between 6 and 12 percent; with your first reading about 1 percent lower. For air-dried stock, the final reading is typically between 12 and 19 percent, with the first reading between 2 and 3 percent lower. Meter readings outside of these ranges indicate that the board is poorly seasoned.

Pin-less meters scan through the cross section of a board taking into account the moisture in the entire penetrated area. If there is a high concentration of moisture at the surface, the reading will be skewed to reflect this surface moisture. If the surface is dry and core moisture exists, the readings will be lower than the representative moisture levels throughout the board.

Does surface moisture skew a delmhorst meter reading?

Moisture caused by exposure to rain, fog or high relative humidity is easily and accurately detected with insulated pins.

If you're using non-insulated pins, push them 1/16" into the wood and read the meter. Then push them to their full penetration. The meter reading should increase by 1 to 2 points, just because of the greater contact. If there is no increase, or the increase is less than 1 percent, the wood is wet on the surface and the readings are unreliable.

As described in the answer to the question above, readings taken with a surface meter are affected by surface moisture, making it difficult to determine if the surface moisture is a result of standing water caused by rain, or if it is representative of the moisture content throughout the board.

How many measurements does delmhorst recommend for an accurate sampling?

Accuracy of the readings depends on how representative the samples are of the entire load. In an ideal situation, when all the boards in a load have the same moisture content, and the distribution in each board is uniform, only a few readings are needed.

But since this ideal condition doesn't often happen, start by checking a large percentage of pieces. If the readings are within close range, it's apparent that the load is fairly uniform. For critical use, check 5 or 10 percent of the load, and be sure to look at boards from all parts of the load. Check slower drying quarter sawn boards as well as flat sawn lumber. If you can only drive pins into the edge, be sure to use the longest pins available to reach the fibers as deep as the board is thick.

The Delmhorst RDM series moisture meters with data collection and statistical analysis capabilities are ideal for simplifying the entire sampling procedure and providing backup documentation.

How far should i drive non-insulated pins into wood?

To full depth if possible. However, at moisture levels below 10%, it is usually sufficient to make good, positive contact with the wood. At higher levels of moisture and especially if you have a steep gradient, full penetration is a must. Otherwise you can have discrepancies between meter readings and actual moisture content of as much as 5 or 6 points, especially in the range above 20 percent. For best results in such cases, use insulated pins.

Do i get the same reading if i use 2-pin insulated or 4-pin non-insulated electrodes?

The original Delmhorst calibration was developed with a 4-pin electrode - four non-insulated steel needles, with 5/16" penetration - in samples with uniform moisture distribution. For greatest accuracy, a small correction is necessary when using electrodes with two insulated pins. The latest Delmhorst models available are calibrated either for the 2-pin electrode only, or are programmable for both 2-pin and 4-pin electrodes.

How does temperature affect the accuracy of meter readings?

After moisture content and a moisture gradient, if one exists, wood temperature is the most important factor affecting the accuracy of your readings. As wood temperature increases its electrical resistance decreases and indicated moisture content rises. The lower the temperature, the lower the indicated moisture content. Depending on the temperature and moisture content, you may have to make a correction.

Delmhorst meters are calibrated at 70° F (20° C). In field use, no correction is necessary if the wood temperature is between 50° F and 90° F. If the temperature correction is not built in the meter, use the slide rule or chart we supply with each meter.

The temperature of the wood does not affect pin-less type meters, unless the lumber is frozen.

Are delmhorst meters accurate on frozen lumber?

As long as the wood is not frozen solid and remains conductive, a pin-type meter will give reliable readings. However, most instrumentation, unless specifically designed for extreme weather conditions, will not work well in constant sub-freezing temperatures.

How do delmhorst meters correct for species variation?

When using a pin-type meter, all species yield different readings at the same moisture content. This is due to the fact that the electrical characteristics of different wood species vary. Delmhorst uses the USDA standard - Douglas Fir - as the basis for all calibrations.

When using a Delmhorst meter on other species, either refer to the species correction chart, or key in your species into one of our microprocessor-based meters for an automatic correction.

Pinless meters also yield different readings for different species. However, instead of electrical characteristics affecting the readings, wood density affects the readings. Refer to the species correction chart enclosed with your meter to adjust the readings accordingly.

Does a group species correction provide an accurate meter reading?

Species corrections are most accurate when handled as an individual correction, either through the a species correction chart, or automatically, through software. While not as accurate as individual corrections, the group correction is adequate for practical purposes, as long as the correction is close to the individual factor for the species.

What about exotic species or other species not on the charts?

If the species correction is simply not available, you can take readings below 10 percent at face value. Any correction is so small that depending on the application; a correction may not be necessary.

A good moisture meter is still valuable, even without a correction factor because you can use it to determine the equilibrium moisture content (EMC). A meter reading by itself is not always as important as allowing the wood to attain its EMC level where it won't change dimension, crack, or split.

Does the glue used in plywood affect meter accuracy?

In most cases, no. To verify this, use insulated pins to make individual tests by touching the outer ply, glue lines, and center plys. If the glue reads the same as wood, use the meter on plywood as you would any solid material and take the readings at face value, without species correction.

What about the chemicals in treated lumber?

Recent studies have shown that you can use a Delmhorst meter with confidence at the treating plant, job site, or when the wood is in service if the preservative is a "C oxide" formulation (CCA-C) widely used today. Our experience has shown that at higher moisture content levels (above 20 percent), chemically treated lumber tends to yield somewhat erratic readings.

What about particleboard and other manufactured materials?

Chemical additives may or may not affect meter readings. Use the meter to make qualitative, comparative readings. If greater accuracy is required, Delmhorst can help you to develop a specific calibration.

How do delmhorst meters handle readings on rough-surfaced lumber and cupped boards?

With a pin-type meter, these conditions are not a problem. Just drive the pins as you would normally, insuring firm, positive contact and detect unknown gradients. Pin-less meters, however, need full exposure to a flat surface so their readings on some uneven surfaces may be unreliable.

Are there board width limitations in using moisture meters?

Board width is not a limiting factor when using a pin type moisture meter. As long as the pins make good contact, the meter can be used on anything from small dowels to wide planks.

For accurate results with a pinless meter, the material you're testing must be at least the width of the scanning area on the bottom of the meter.

What happens if i bring a delmhorst meter into a dry kiln?

Moisture meters, like most precision instruments, are sensitive to moisture. We do not recommend taking a meter into a kiln, especially from cold surroundings. If you must, take a few minutes to warm up the meter and electrode to a maximum 100°F, so that the higher temperature and moisture levels in the kiln will not affect the meter for a few minutes. If you don't acclimate the meter, readings will be erratic at best.

While Delmhorst meters are built for the harsh mill environment, continued exposure to high heat and humidity will invite corrosion and shorten the life of a meter's keypad, display and PC board components.

How can i monitor moisture content during drying without going into the kiln?

Use the Delmhorst Kil-Mo-Trol, a remote probe system that measures the moisture content of lumber during the drying process. Resistance probes or contact pins are located at various "stations" throughout the lumber packages to monitor shell and core or core only moisture content readings. This technique is proven for both hardwood and softwood drying, and can be used in any type of dry kiln, pre-dryer, or air-drying operation. For more information about Kil-Mo-Trol, please close this window and click on the Kil-Mo-Trol Moisture Monitor button.

How does static electricity affect meter readings?

In cold and/or dry climates, static charges may cause erratic meter readings in the range below 8 percent. Measuring such high resistance under these conditions is difficult enough, but the winter months can make it more so. The analog meter pointer "jumps" all over the scale or the digital display may flash erratic numbers. To minimize the effect of static:

  • Try not to let the electrode cable dangle.
  • Drive the electrode pins into the wood with the meter turned off, and then turn the meter on when you are ready to take the reading.
  • After driving the pins, place your hands next to them on each side of the electrode to help discharge the static from the board.
  • You can also try passing a damp cloth over the board's surface to pick up any static charges before driving the pins.

Depending on the conditions, any one of them can work, either alone or in combination with another.

Why do meter readings not always agree?

If two meters are not of the same manufacturer, readings will likely not correspond, because of the different calibrations used. Made in the USA, Delmhorst meters are calibrated on the USDA standard, while foreign made meters use other standards and often have different species and temperature correction factors.

Even readings on two meters of the same manufacturer may vary. Assuming both meters are electrically correct, the difference usually can be attributed to use of different electrodes, pin penetration, and species and temperature corrections. When meters are used for lumber inspections by vendors and buyers, the two parties should have a basis for comparing readings obtained with the instruments they are using.

How do i keep a delmhorst meter in good working condition?

Delmhorst moisture meters are well known for their ruggedness and ability to withstand years of rough handling. Like any testing instrument, a little care goes a long way toward trouble-free service:

  • Store the meter in clean, dry place
  • Change batteries and pins as needed
  • Keep the meter and electrode clean by using any biodegradable cleanser sparingly on external parts only.

If you have any doubt about the working condition of your meter, send it to Delmhorst. We can repair and re-calibrate your instrument to its original standards and return it to you quickly.



  • Delmhorst BD-10 Analog Pin-Type Moisture Meter for Building Inspection

    Delmhorst BD-10 Analog Pin-Type Moisture Meter for Building Inspection
    Price: $465.00 - $735.00

    Delmhorst BD-10 Analog Pin-Type Moisture Meter for Building Inspection
    Easy-to-read analog display.
    Built-in calibration check.
    Integral contact pins mounted on top of meter provide 5/16” penetration.
  • Delmhorst BDX-20 Pin-Type Moisture Meter for Building Inspection

    Delmhorst BDX-20 Pin-Type Moisture Meter for Building Inspection
    Price: $440.00 - $540.00

    Large, custom display with auto backlight - easy to read under all conditions
    Wood temperature correction (°F/°C)
    Alarm set point - alerts to user-selected MC level
  • Delmhorst BDX-30 Pin-Type Moisture Meter for Building Inspection

    Delmhorst BDX-30 Pin-Type Moisture Meter for Building Inspection
    Price: $540.00 - $885.00

    Delmhorst EDGE™ app with Bluetooth® connectivity
    Large, custom display with auto backlight - easy to read under all conditions
    Species/Materials – download up to 15 into the meter out of 37 available
  • Delmhorst CX-30 Moisture Meters for Cotton

    Delmhorst CX-30 Moisture Meters for Cotton
    Price: $550.00

    Large, custom display with auto backlight - easy to read under all conditions
    Bluetooth® connectivity
    Color-coded LED's - adjustable through EDGE™ app
  • Delmhorst G-34 Hops Moisture Meter

    Delmhorst G-34 Hops Moisture Meter
    Price: $575.00 - $740.00

    Delmhorst G-34 Hops Moisture Meter
    Easy-to-read analog display
    Moisture Range: 7%-14% on hops
    Built-in battery and calibration check.
  • Delmhorst G-7 Grain Moisture Meter

    Delmhorst G-7 Grain Moisture Meter
    Price: $620.00

    Delmhorst G-7 Grain Moisture Meter
    Built-in calibrations for barley, coffee, corn, flax, hay, oats, pasta, rapeseed, rough rice, rye, sorghum, soybeans, and wheat.
    Built-in temperature correction over the range of 32 - 160° F (0 - 70° C).
    Programmable offset to match elevator.
  • Delmhorst HT-4000F Thermo-Hygrometer

    Delmhorst HT-4000F Thermo-Hygrometer
    Price: $775.00

    Delmhorst HT-4000F Thermo-Hygrometer
    Bright, clear digital display.
    Relative Humidity Range: 0% - 100%, sensor can be used for in-situ concrete testing following the ASTM F2170 standard
    Temperature Range: -40°F - 255°F (-40°C - 124°C).
  • Delmhorst HTX-30 All-Purpose Thermo-Hygrometer

    Delmhorst HTX-30 All-Purpose Thermo-Hygrometer
    Price: $525.00 - $575.00

    The next generation of moisture meters is here, with the introduction of the Navigator™
    Series and EDGE ™app from Delmhorst
  • Delmhorst J-4 Analog Pin-Type Wood Moisture Meter

    Delmhorst J-4 Analog Pin-Type Wood Moisture Meter
    Price: $385.00 - $570.00

    Delmhorst J-4 Analog Pin-Type Wood Moisture Meter
    Easy-to-read analog display.
    Moisture Range: 6%-30% on wood.
    Built-in calibration check.
  • Delmhorst J-Lite Pin-Type Wood Moisture Meter

    Delmhorst J-Lite Pin-Type Wood Moisture Meter
    Price: $225.00

    Delmhorst J-Lite Pin-Type Wood Moisture Meter
    12 bright LEDs - Great for reading in direct sunlight or dark areas.
    Moisture Range: 6% - 30%.
    Built-in calibration check.
  • Delmhorst JLX-30 Moisture Meters for Leather

    Delmhorst JLX-30 Moisture Meters for Leather
    Price: $535.00

    Large, custom display with auto backlight - easy to read under all conditions
    Bluetooth® connectivity
    Color-coded LED's - adjustable through EDGE™ app
  • Delmhorst JX-20 Wood Moisture Meters

    Delmhorst JX-20 Wood Moisture Meters
    Price: $425.00 - $595.00

    Large, custom display with auto backlight – easy to ready under all conditions
    MC Range – 6%-60% Wood (Douglas Fir)
    Species - 74 included