SC-PM Display Unit

See More Tension Indicators & Amplifiers
SC-PM Display Unit

SC-PM Display Unit

See More Tension Indicators & Amplifiers
Call for price
  • FREE Ground Shipping on Orders Over $150
warrenty
Customer Reviews

Product Description

Display Unit


3 different calibrations for customer supplied material can be saved at this display unit

Panel mount digital tension indicator (1/8 Din Cutout) with analog output and user-set MIN and MAX alarm limits. RS-232 output is optional. Can be used with all 3-roller tension sensors TE, TF, TSW, TS2 and other sensors that provide an analog output signal 0 - 1V DC.

3 different calibrations for customer supplied material can be saved at this display unit

Available with RS232 or RS422 output for direct connection to PC

Rear Panel of Indicator: Terminal strip for power supply, output signals (RS 232, 0 - 10 V DC, Open Collector)


line
Kit Contents
line

  • SC-PM Display Unit
  • operating instruction
  • transport packaging


line
Features
line

  • Connection of series TE, TF, TSW, TS2 and other with analog output 0 - 1 V DC, optionally series without integrated amplifier
  • User set limits (Min and Max alarms) with LED and Open Collector output for external signal unit
  • Adjustable damping for easier reading if tension fluctuates
  • Panel mounted digital display
  • Display unit with Dotmatrix LCD display, 12 mm high with backlight
  • Interfaces:
    • Analog: 0 - 10 V DC (standard)
    • Digital (optional): RS 232 or RS 422
    • Current (optional): 4 - 20 mA (instead of 0 - 10 V DC output)
  • Can store up to three (3) separate calibrations for 3 different materials
  • CE certified
  • Scale to desired engineering units of grams, Kg, Lbs, cN, daN


line
Specifications
line

Digital displayDotmatrix LCD, 12 mm high with backlight
Measuring UnitscN, daN, g, kg or lb, user- selectable depending on range
Selectable Damping9 adjustable settings (electronic damping, moving averaging)
Output signalanalog: 0 - 10 V DC /R (Last) ≥ 5 kΩ
digital (option): RS 232 or RS 422 (19200, 8, N, 1), 100 measurings/s
current (option): 4 - 20 mA instead of 0 - 10 V DC
Input signal0 - 1 V DC, option mV
Alarm limitsProgrammable MIN/MAX limits with LED
Alarm outputOpen Collector max. 30 V DC, 10 mA
AdjustmentStorage for 3 different materials (standard adjustment + 2 customer supplied materials)
Power RequiredSC-PM: 15 - 24 V DC, 100 mA (Regulated)
SC-PM-AC: 100-240V AC, using AC/DC Adapter (plugs into AC wall outlet)
Temperature range10 - 45° C
Air humidity85 % RH, max.
HousingPlastics
Dimensions115 x 95 x 48 mm (LxWxH), mounting cut out 92 x 44 mm
Weight, net (gross)Approx. 300 g (Approx. 1000 g)


line
Output Signal
line

Standard
analog 0 - 10 V DC
open collector
Code A3
4 - 20 mA instead of 0 - 10 V DC
open collector
Code 232
digital RS-232
analog 0 - 10 V DC
open collector
Up to 100 readings can be transfered per second
Code 422
digital RS-422
analog 0 - 10 V DC
open collector
Up to 100 readings can be transfered per second


line
Downloads
line

SC-PM Display Unit - Instruction Manual
SC-PM Display Unit - Output Signal - Code 422
SC-PM Display Unit - Output Signal - Standard
SC-PM Display Unit - Output Signal - Code 232
SC-PM Display Unit - Output Signal - Code A3