    Product Description
    DeFelsko RTRH1-G PosiTector RTR H1 Standard Replica Tape Reader / Surface Profile Gage
    Surface Profile Gage for Blasted Steel and Textured Coatings
    Digital spring micrometers measure and record surface profile parameters using Testex Press-O-Film replica tape
    Ready to measure - no calibration adjustment required for most applications

    Electronic Surface Profile Gage for Blasted Steel and Textured Coatings

    Digital spring micrometers measure and record surface profile parameters using Testex Press-O-Film™ replica tape—producing a more accurate peak-to-valley height measurement.

    • Ready to measure—no calibration adjustment required for most applications
    • NEW Larger 2.8" impact resistant color touchscreen with redesigned keypad for quick menu navigation
    • NEW Weatherproof, dustproof, and water-resistant—IP65-rated enclosure
    • PosiTector interchangeable platform—attach any PosiTector probe to a single gage body
    • USB, WiFi, and Bluetooth connectivity to PosiSoft PC, Mac, and Smartphone software
    • Certificate of Calibration showing traceability to PTB included (Long Form)

    Conforms to ASTM D4417, ISO 8503-5, NACE RP287, SSPC-PA 17, SSPC-SP5, SP6, SP10, SP11-87T, and others


    line
    Kit Contents
    line

    The DeFelsko PosiTector RTR H1 Standard Surface Profile Gage includes everything needed for testing:

    • PosiTector Standard Gage Body BDYSTD
    • PosiTector RTR H Probe PRBRTRH
    • Stainless steel burnishing tool and 5 cleaning cards
    • Surface cleaning putty and check shim(s)
    • Protective lens shield with belt clip
    • Wrist strap and protective rubber holster with belt clip
    • 3 AAA alkaline batteries
    • PosiSoft Software and USB cable
    • Long Form Certificate of Calibration traceable to PTB
    • Nylon carrying case shoulder strap and instructions
    • Two (2) year warranty


    line
    Features
    line

    Simple

    • Measures peak height (HL)
    • Automatically subtracts the 50.8 μm (2 mils) incompressible film from all readings
    • Minimizes inspector workload by reducing the number of replicas needed to ensure accuracy
    • NEW Larger 2.8" impact resistant color touchscreen with redesigned keypad for quick menu navigation
    • NEW On-gage help explains menu items at the touch of a button
    • RESET feature instantly restores factory settings
    • Durable
    • NEW Weatherproof, dustproof, and water-resistant—IP65-rated enclosure
    • Rugged indoor/outdoor instrument—ideal for field or shop use
    • NEW Ergonomic design with durable rubberized grip
    • Shock-absorbing, protective rubber holster for added impact resistance
    • Two year warranty on gage body AND probe

    Accurate

    • Produces a more accurate peak-to-valley height measurement. See linearized peak height (HL)
    • Certificate of Calibration showing traceability to PTB included (Long Form)
    • Conforms to national and international standards including ISO 8503-5, ASTM D4417 Method C, NACE RP0287 and SSPC-PA17

    Versatile

    • PosiTector body accepts all PosiTector RTR, SPG, 6000, 200, DPM, IRT, SST, SHD, BHI, and UTG probes easily converting from a surface profile gage to a coating thickness gage, dew point meter, soluble salt tester, hardness tester, or ultrasonic wall thickness gage
    • Mils/Microns switchable
    • Selectable display languages
    • NEW Auto rotating display with Flip Lock

    Powerful

    • Statistics mode continually displays/updates average, standard deviation, min/max, and number of readings while measuring
    • NEW Screen Capture—save 100 screen images for record keeping and review
    • NEW Instant-on feature quickly powers up the gage if recently powered down
    • NEW Up to 30% longer battery life
    • USB port for fast, simple connection to a PC and to supply continuous power. USB cable included
    • PosiSoft USB Drive—stored readings and graphs can be accessed using universal PC/Mac web browsers or file explorers. No software required.
    • Every stored measurement is date and time stamped
    • Software Solutions for viewing, analyzing & reporting data
    • Software Updates via web keep your gage current


    line
    Standard Model Features
    line

    Includes ALL features as shown above plus:

    • NEW Storage of 1,000 readings per probe—stored readings can be viewed or downloaded


    line
    Specifications
    line

    Peak Height (HL) Measurement Range20 to 115 μm (0.8 to 4.5 mils)
    Peak Height (HL) Accuracy± 5 μm (± 0.2 mils)
    Peak Height (HL) Resolution1 μm (0.1 mil)
    Anvil DiameterØ6.35 mm (Ø0.25 inch)
    Anvil Pressure110 gram-force (1.1 Newtons)
    Size 152 x 61 x 28 mm | (6" x 2.4" x 1.1")
    Weight 140 g (4.9 oz.) without batteries


    line
    Probe Specifications

    Peak Height (HL) Measurement Range20 - 115 μm
    0.8 - 4.5 mils
    Peak Height (HL) Accuracy ± 5 μm (± 0.2 mils)
    Peak Height (HL) Resolution1 μm (0.2 mils)
    Anvil DiameterØ6.3 mm (Ø0.25 inch)
    Anvil Pressure110 gram-force (1.1 Newtons)


    lineHow It Works
    line

    Click to View DeFelsko PosiTector RTR-H Surface Profile Gage How It Works


    lineSoftware
    line

    Four FREE and unique ways to view and report your PosiTector and PosiTest data. Learn More


    line
    Downloads
    line

    DeFelsko PosiTector RTR HSurface Profile Gage for Blasted Steel and Textured Coatings - Literature
    DeFelsko PosiTector RTR HSurface Profile Gage for Blasted Steel and Textured Coatings - Instruction Manual
    DeFelsko PosiTector RTR HSurface Profile Gage for Blasted Steel and Textured Coatings - Linearization of Roughness Measurements
    DeFelsko Accessories for Inspection Instruments - Online Catalog

    F.A.Q.

    Is the PosiTector RTR H calibrated at the factory?

    The PosiTector RTR arrives fully calibrated and ready to measure. A Long-Form Certificate of Calibration traceable to NIST is included, which documents actual readings taken by your instrument at our calibration laboratory on standards traceable to a national metrology institute. Beware of 'Certificates' or 'Certificates of Conformance' offered by competitors. These typically do not include actual instrument readings, and are often insufficient to meet common quality requirements.

    Verification of gage calibration and accuracy can be performed with the supplied check shim, which is specifically intended for all PosiTector RTR probes. 

    What is replica tape?

    Testex Replica Tape is a long-known method for characterizing a surface. It is simple, relatively inexpensive, and shows good correlation with results from other methods. It has the advantages of ruggedness, relatively low start-up cost, good repeatability and the option of retaining a physical replica of the surface being evaluated. The method is widely used and widely understood. It is particularly useful for measurements on curved surfaces that are difficult to measure directly with other instruments.

    It is therefore not surprising that it has become the most popular field method for measuring surface profile. Its operation is described in a number of international standards including ASTM D4417, ISO 8503-5, NACE SP0287, and AS 3894.5.


    What grades of replica tape is the PosiTector RTR H compatible with?

    The PosiTector RTR measures the two primary grades of Testex Replica Tape: Coarse and X—Coarse. The other grades of replica tape, Coarse Minus and X—Coarse Plus, are check grades that are used only to confirm or improve the accuracy of conventional analog spring micrometer measurements at the lower end of the Coarse tape's range (Coarse Minus) and at the upper end of the X—Coarse tape's range (X—Coarse Plus). Since the PosiTector RTR automatically corrects for the non—linearity of Coarse and X—Coarse tape, these other check grades are not required.

    Why should I purchase the PosiTector RTR H over a conventional snap gage?

    The PosiTector RTR offers a number of advantages over a mechanical spring micrometer:

    • Linearization feature increases measurement accuracy and reduces tape consumption.
    • Unique opposing spring design prevents undesired user interferences from occurring.
    • Large digital display for clear, easy-to-read measurements with the ability to store and download readings.
    • Arrives fully calibrated and includes a traceable calibration certificate.
    • Interchangeable probe design offers the ability to use a single PosiTector gage body for a wide variety of applications: surface profile, coating thickness, wall thickness, salt contamination, Shore hardness and environmental.

    Is the PosiTector RTR H as accurate as conventional spring micrometers?

    The PosiTector RTR's displayed HL (linearized height) value is a more accurate surface profile measurement because it adjusts for tape non—linearity without the need to average the results from 2 or more replicas. Linearization is a technique used to insure uniform accuracy of measurement in many types of advanced sensors. Its use in connection with replica tape is described here.

    Do I need to take two measurements in some surface profile ranges with the PosiTector RTR H, as is required with the spring micrometer?

    No. With a single measurement, the gage produces a more accurate peak—to—valley height measurement HL. The advantages are a reduction in measurement uncertainty, inspector workload, the likelihood of error, and the number of replicas needed by inspectors to assure accuracy.

    Together with Testex, DeFelsko determined the non—linear relationship between actual steel profile peak—to—valley heights and their replicated heights on tape. By adjusting for this non-linearity, the PosiTector RTR is able to overcome the shortcomings imposed by replica tape foam.

    Why does the blasted steel under the burnished replica tape appear shiny, and different from the surrounding area?

    Abrasive blasting often leaves debris on the surface, which changes its appearance. If the surface isn't cleaned with the included cleaning putty before measuring, the replica tape captures this debris and 'cleans' the surface where the tape was burnished. This may make the test area appear 'shiny' compared to the surrounding area, and is not a sign of damage to the blast profile.

    How do you position replica tape into the PosiTector RTR H?

    Testex Press—O—Film Replica Tape is produced with two positioning dots that align with arrows located on both sides of the PosiTector RTR's probe. Move the tape to the back of the probe, align the dots, and then press the two probe buttons. Measurement is fast, simple and accurate.

    Should I purchase the PosiTector RTR Replica Tape Reader or PosiTector SPG Surface Profile Gage for my application?

    Both instruments conform to ASTM D4417 "Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned Steel".

    The PosiTector SPG conforms to Method B of ASTM D4417. The PosiTector SPG measures quickly, and has no per-test cost. It keeps a digital record of each measurement, is less operator dependent, as no burnishing of replica tape is required. It also has a greater range than replica tape.

    The PosiTector RTR conforms to Method C of ASTM D4417. It is used together with Testex Replica Tape, a widely used and respected method to measure surface profile. It has the ability to measure on curved surfaces, and gives the user the option to retain the replica tape; a physical replica of the tested surface.

    What is the spring pressure on the probe? Do I have to apply a specific pressure to the buttons?

    The anvil impact force of the PosiTector RTR is identical to that of conventional mechanical spring micrometers. The PosiTector RTR has the same anvil size (0.25 inch / 6.25mm diameter) and applies the same spring tension (110 gram—force / 1.1 Newtons) as Testex micrometers and as required by major test standards.

    An issue with mechanical spring micrometers is that they can under—read if a user drops the measuring anvils onto the replica tape too fast. Other errors can occur if the user presses upward on measuring arms to “stabilize” readings. Both actions force conventional micrometers to read lower by crushing the tape's delicate microfoam.

    The PosiTector RTR's unique opposing spring design prevents these undesired user interferences from occurring. Pressing the two probe buttons releases a holding spring. That allows a second spring, the anvil spring, to apply a constant pressure measuring force on the replica. This measuring force is not coupled to the buttons so the user cannot alter the applied pressure and inadvertently influence results.

    How often should the PosiTector probe be recalibrated?

    PosiTector probes include a Certificate of Calibration showing traceability to NIST or PTB included (Long Form) with each probe—with no expiry or end date. They have no shelf life, therefore the length of time in the field is not a good indicator for recalibration intervals. Many organizations with quality programs and recertification programs require annual recalibrations, and this is a good starting point for most users. DeFelsko recommends that customers establish calibration intervals based upon their own experience and work environment. Based on our product knowledge, data and customer feedback, a one year calibration interval from the date the instrument was placed in service is a good starting point.